Master index | Index for vbmeg/functions/device/eeg |
vb_bdffile_get_info | read BDF file |
vb_eeg_get_active_trigger_channel | extract active trigger channels by reading status channel data |
vb_eeg_make_channel_bit_array | make bit arrays of specified channels |
vb_eegfile_add_position | overwrite position data from POS-MAT file for EEG-MAT file |
vb_eegfile_filter_ch_data | make new external channel data files after filtering |
vb_eegfile_get_channel_label | return valid channel label list from eegfile |
vb_eegfile_get_sampling_frequency | return valid sampling frequency from EEG-MAT file |
vb_eegfile_get_sensor_number | return number of sensor |
vb_eegfile_get_sensor_position | return coordinates of sensor positions |
vb_eegfile_load_coordtype | read coordinate type from EEG-MAT file |
vb_eegfile_load_data | load eeg data file and return eeg data (Nchannel x Nsample x Ntrial) |
vb_eegfile_load_eeginfo | return EEGinfo in EEG-MAT file |
vb_eegfile_load_internal_data | return eeg data which is saved as an internal parameter in EEG-MAT file |
vb_eegfile_make_channel_info | make ChannelInfo from channel label |
vb_eegfile_remake_for_LF | make lightweight eeg.mat file for calculating leadfield |
vb_eegfile_replace_label | replace channel labels of eegfile |
vb_eegfile_trial_ch_data | Make trial data files after extracting trials from continuous raw data |
vb_eegfile_update_data | Replace data and update EEG-MAT file. |
vb_eeginfo_add_history | add history information to EEGinfo |
vb_eeginfo_get_channel_index | return channel index list |
vb_eeginfo_get_channel_label | return channel label list from EEGinfo struct |
vb_eeginfo_get_channel_label_extra | return extra channel label list from EEGinfo struct |
vb_eeginfo_get_channel_number | return channel number from EEGinfo struct |
vb_eeginfo_get_datadir | < |
vb_eeginfo_get_datatype | < |
vb_eeginfo_get_device | < |
vb_eeginfo_get_header | return header data of Biosemi from EEGinfo |
vb_eeginfo_get_post_trigger | return post-trigger from current EEGinfo struct |
vb_eeginfo_get_pre_trigger | return pre-trigger from current EEGinfo struct |
vb_eeginfo_get_read_channels | return channel list to be read by channel list and read switch |
vb_eeginfo_get_rectime | return record time from EEGinfo |
vb_eeginfo_get_reference | return reference data from EEGinfo |
vb_eeginfo_get_sample_number | < |
vb_eeginfo_get_sampling_frequency | return sampling frequency from EEGinfo struct |
vb_eeginfo_get_sensor_number | return number of sensor |
vb_eeginfo_get_sensor_position | get sensor position data from EEGinfo struct |
vb_eeginfo_get_trigger_status_label | recognize trigger and status channel by label of transducer |
vb_eeginfo_get_version | return version data from EEGinfo |
vb_eeginfo_make_channel_info | make ChannelInfo from channel label |
vb_eeginfo_set_header | set header data of Biosemi to EEGinfo |
vb_eeginfo_set_post_trigger | set post-trigger value to current EEGinfo struct |
vb_eeginfo_set_pre_trigger | set pre-trigger to current EEGinfo struct |
vb_eeginfo_set_rectime | set record time to EEGinfo |
vb_eeginfo_set_reference | set reference type to EEGinfo |
vb_eeginfo_set_sensor_position | set sensor position data to EEGinfo struct |
vb_eeginfo_set_version | set version data to EEGinfo |
vb_job_eeg_biosemi | make EEG-MAT file from BDF file |
vb_job_eeg_brainamp | make EEG-MAT file from BrainAmp files. |
vb_job_eeg_gateway | This is a gateway function to job_eeg. |