{"id":563,"date":"2017-12-08T17:46:06","date_gmt":"2017-12-08T08:46:06","guid":{"rendered":"http:\/\/vbmeg.atr.jp\/v30\/?page_id=563"},"modified":"2024-10-07T10:26:40","modified_gmt":"2024-10-07T01:26:40","slug":"tutorials","status":"publish","type":"page","link":"https:\/\/vbmeg.atr.jp\/v30\/documentation\/tutorials\/","title":{"rendered":"Tutorials"},"content":{"rendered":"<h3>Source imaging with GUI<\/h3>\n<ul>\n<li><span style=\"font-size: large;\"><strong><a href=\"https:\/\/vbmeg.atr.jp\/docs\/v30\/static\/vbmeg3_tutorial_auditory.html\">MEG source imaging<\/a><\/strong><\/span><br \/>\nThis tutorial is for the beginner of VBMEG. Using the graphical user interface (GUI), this tutorial guides through the procedures from importing raw MEG data to estimating a source current.<br \/>\n<span style=\"padding: 0.3em; background: #bae8e8; color: #272343; font-size: smaller;\">INPUT<\/span> MEG\u00a0\u00a0<span style=\"padding: 0.3em; background: #ffd803; color: #272343; font-size: smaller;\">OUTPUT<\/span> Source current\u00a0\u00a0<span style=\"padding: 0.3em; background: #272343; color: white; font-size: smaller;\">WITH<\/span> GUI<\/li>\n<\/ul>\n<h3>Source imaging with scripts<\/h3>\n<ul>\n<li><span style=\"font-size: large;\"><a href=\"https:\/\/vbmeg.atr.jp\/docs\/v30\/static\/vbmeg3_meeg_source_imaging.html\"><strong>M\/EEG source imaging<\/strong><\/a><\/span><br \/>\nUsing scripts, this tutorial guides through the procedures from importing raw EEG\/MEG data to estimating source currents.<br \/>\n<span style=\"padding: 0.3em; background: #bae8e8; color: #272343; font-size: smaller;\">INPUT<\/span> MEG, EEG\u00a0\u00a0<span style=\"padding: 0.3em; background: #ffd803; color: #272343; font-size: smaller;\">OUTPUT<\/span> Source current\u00a0\u00a0<span style=\"padding: 0.3em; background: #272343; color: white; font-size: smaller;\">WITH<\/span> Scripts<\/li>\n<\/ul>\n<ul>\n<li><span style=\"font-size: large;\"><a href=\"https:\/\/vbmeg.atr.jp\/docs\/v30\/static\/vbmeg3_meg_group_analysis.html\"><strong>MEG source imaging and group analysis<\/strong><\/a><\/span><br \/>\nThis tutorial guides through the procedures from importing raw MEG data to a group analysis of source currents.<br \/>\n<span style=\"padding: 0.3em; background: #bae8e8; color: #272343; font-size: smaller;\">INPUT<\/span> MEG\u00a0\u00a0<span style=\"padding: 0.3em; background: #ffd803; color: #272343; font-size: smaller;\">OUTPUT<\/span> Statistical significance \u00a0<span style=\"padding: 0.3em; background: #272343; color: white; font-size: smaller;\">WITH<\/span> Scripts<\/li>\n<\/ul>\n<ul>\n<li><span style=\"font-size: large;\"><a href=\"https:\/\/vbmeg.atr.jp\/docs\/v30\/static\/vbmeg3_only_eeg_source_imaging.html\"><strong>Source imaging only from EEG data<\/strong><\/a><\/span><br \/>\nThis tutorial is for the case where structural MRIs and sensor locations are not available. Here, source currents are estimated only from EEG data by substituting a subject\u2019s structural MRI and sensor locations with the standard ones.<br \/>\n<span style=\"padding: 0.3em; background: #bae8e8; color: #272343; font-size: smaller;\">INPUT<\/span> EEG \u00a0<span style=\"padding: 0.3em; background: #ffd803; color: #272343; font-size: smaller;\">OUTPUT<\/span> Source current\u00a0\u00a0<span style=\"padding: 0.3em; background: #272343; color: white; font-size: smaller;\">WITH<\/span> Scripts<\/li>\n<\/ul>\n<ul>\n<li><span style=\"font-size: large;\"><a href=\"https:\/\/vbmeg.atr.jp\/docs\/v30\/static\/vbmeg3_rs_meeg_source_imaging.html\"><strong>Source imaging from resting-state M\/EEG data<\/strong><\/a><\/span><br \/>\nThis tutorial demonstrates the source imaging from resting-state EEG and MEG data using a beamformer.<br \/>\n<span style=\"padding: 0.3em; background: #bae8e8; color: #272343; font-size: smaller;\">INPUT<\/span> MEG, EEG\u00a0\u00a0<span style=\"padding: 0.3em; background: #ffd803; color: #272343; font-size: smaller;\">OUTPUT<\/span> Source current\u00a0\u00a0<span style=\"padding: 0.3em; background: #272343; color: white; font-size: smaller;\">WITH<\/span> Scripts<\/li>\n<\/ul>\n<ul>\n<li><span style=\"font-size: large;\"><a href=\"https:\/\/vbmeg.atr.jp\/docs\/v30\/static\/vbmeg3_opm_simulation_test.html\"><strong>OPM simulation test<\/strong><\/a><\/span><br \/>\nUsing simulated data, this tutorial demonstrates the source imaging from MEG data recorded with an optically pumped magnetometer (OPM).<br \/>\n<span style=\"padding: 0.3em; background: #bae8e8; color: #272343; font-size: smaller;\">INPUT<\/span> Simulated OPM \u00a0<span style=\"padding: 0.3em; background: #ffd803; color: #272343; font-size: smaller;\">OUTPUT<\/span> Source current\u00a0\u00a0<span style=\"padding: 0.3em; background: #272343; color: white; font-size: smaller;\">WITH<\/span> Scripts<\/li>\n<\/ul>\n<ul>\n<li><span style=\"font-size: large;\"><a href=\"https:\/\/vbmeg.atr.jp\/docs\/v30\/static\/vbmeg3_ose_tutorial.html\"><strong>Source imaging from OSE dataset.<\/strong><\/a><\/span><br \/>\nThis tutorial guides OPM-MEG, SQUID-MEG, and EEG data analysis from importing raw data to source analysis using the OSE dataset.<br \/>\n<span style=\"padding: 0.3em; background: #bae8e8; color: #272343; font-size: smaller;\">INPUT<\/span> OPM, MEG, EEG <span style=\"padding: 0.3em; background: #ffd803; color: #272343; font-size: smaller;\">OUTPUT<\/span> Source current\u00a0\u00a0<span style=\"padding: 0.3em; background: #272343; color: white; font-size: smaller;\">WITH<\/span> Scripts<\/li>\n<\/ul>\n<h3>Connectivity analysis with scripts<\/h3>\n<ul>\n<li><span style=\"font-size: large;\"><a href=\"https:\/\/vbmeg.atr.jp\/docs\/v30\/static\/vbmeg3_sfi_ind.html\"><strong>Signal flow imaging using individual connectome<\/strong><\/a><\/span><br \/>\nFrom source currents and anatomical connectivity estimated from diffusion MRIs (dMRIs), VBMEG can reveal signal flows between brain regions. This tutorial demonstrates the procedures to make movies displaying the signal flows.<br \/>\n<span style=\"padding: 0.3em; background: #bae8e8; color: #272343; font-size: smaller;\">INPUT<\/span> Source current, dMRI \u00a0<span style=\"padding: 0.3em; background: #ffd803; color: #272343; font-size: smaller;\">OUTPUT<\/span> Signal flows \u00a0<span style=\"padding: 0.3em; background: #272343; color: white; font-size: smaller;\">WITH<\/span>Scripts<\/li>\n<\/ul>\n<ul>\n<li><span style=\"font-size: large;\"><a href=\"https:\/\/vbmeg.atr.jp\/docs\/v30\/static\/vbmeg3_sfi_ave.html\"><strong>Signal flow imaging using average connectome<\/strong><\/a><\/span><br \/>\nThis tutorial is for the case where dMRIs are not available. Here, signal flows are estimated from source currents and average anatomical connectivity estimated from publicly available 18 subjects\u2019 dMRIs.<br \/>\n<span style=\"padding: 0.3em; background: #bae8e8; color: #272343; font-size: smaller;\">INPUT<\/span> Source current \u00a0<span style=\"padding: 0.3em; background: #ffd803; color: #272343; font-size: smaller;\">OUTPUT<\/span> Signal flows \u00a0<span style=\"padding: 0.3em; background: #272343; color: white; font-size: smaller;\">WITH<\/span> Scripts<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Source imaging with GUI MEG source imaging This tutorial is for the beginner of VBMEG. Using the graphical user interface (GUI), this tutorial guides through the procedures from importing raw MEG data to estimating a source current. INPUT MEG\u00a0\u00a0OUTPUT Source current\u00a0\u00a0WITH GUI Source imaging with scripts M\/EEG source imaging Using scripts, this tutorial guides through the procedures from importing raw EEG\/MEG data to estimating source currents. INPUT MEG, EEG\u00a0\u00a0OUTPUT Source current\u00a0\u00a0WITH Scripts MEG source imaging and group analysis This tutorial guides through the procedures from importing raw MEG data to a group analysis of source currents. INPUT MEG\u00a0\u00a0OUTPUT Statistical significance \u00a0WITH Scripts Source imaging only from EEG data This tutorial &hellip; <a href=\"https:\/\/vbmeg.atr.jp\/v30\/documentation\/tutorials\/\" class=\"more-link\">Continue reading <span class=\"screen-reader-text\">Tutorials<\/span> <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":973,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-563","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vbmeg.atr.jp\/v30\/wp-json\/wp\/v2\/pages\/563","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vbmeg.atr.jp\/v30\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vbmeg.atr.jp\/v30\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vbmeg.atr.jp\/v30\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vbmeg.atr.jp\/v30\/wp-json\/wp\/v2\/comments?post=563"}],"version-history":[{"count":125,"href":"https:\/\/vbmeg.atr.jp\/v30\/wp-json\/wp\/v2\/pages\/563\/revisions"}],"predecessor-version":[{"id":1130,"href":"https:\/\/vbmeg.atr.jp\/v30\/wp-json\/wp\/v2\/pages\/563\/revisions\/1130"}],"up":[{"embeddable":true,"href":"https:\/\/vbmeg.atr.jp\/v30\/wp-json\/wp\/v2\/pages\/973"}],"wp:attachment":[{"href":"https:\/\/vbmeg.atr.jp\/v30\/wp-json\/wp\/v2\/media?parent=563"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}