Home > vbmeg > functions > gui > preAnalysis > meeg_processor > signal_processor > vb_signal_processor_update_screen.m

vb_signal_processor_update_screen

PURPOSE ^

Update GUI.

SYNOPSIS ^

function data = vb_signal_processor_update_screen(data)

DESCRIPTION ^

 Update GUI.
 [USAGE]
    data = vb_signal_processor_update_screen(data);
 [IN]
    data : Application data.
 [OUT]
    data : Application data.

 Copyright (C) 2011, ATR All Rights Reserved.
 License : New BSD License(see VBMEG_LICENSE.txt)

CROSS-REFERENCE INFORMATION ^

This function calls: This function is called by:

SOURCE CODE ^

0001 function data = vb_signal_processor_update_screen(data)
0002 % Update GUI.
0003 % [USAGE]
0004 %    data = vb_signal_processor_update_screen(data);
0005 % [IN]
0006 %    data : Application data.
0007 % [OUT]
0008 %    data : Application data.
0009 %
0010 % Copyright (C) 2011, ATR All Rights Reserved.
0011 % License : New BSD License(see VBMEG_LICENSE.txt)
0012 
0013 %
0014 % --- Previous check
0015 %
0016 if ~exist('data', 'var')
0017     error('data is a required paraemter.');
0018 end
0019 
0020 %
0021 % --- Main Procedure
0022 %
0023 H = data.H;
0024 d = vb_define_signal_processor;
0025 
0026 %%%%%%%%%%%%%%%%%%%%%%%%
0027 % Input MEG/EEG file list
0028 set(H.input_file_listbox, 'String', data.input_files);
0029 
0030 % Adjust focus line
0031 selected = get(H.input_file_listbox, 'Value');
0032 if isempty(selected) || selected <= 0
0033     selected = 1;
0034     set(H.input_file_listbox, 'Value', 1);
0035 end
0036 Nfiles     = length(data.input_files);
0037 if selected > Nfiles && selected ~= 1
0038     selected = Nfiles;
0039     set(H.input_file_listbox, 'Value', Nfiles);
0040 end
0041 
0042 % Change View button status
0043 if isempty(data.input_files) || ...
0044    exist(data.input_files{selected}, 'file') ~= 2
0045     set(H.input_file_remove_push, 'Enable', 'off');
0046     set(H.input_file_view_push, 'Enable', 'off');
0047 else
0048     set(H.input_file_remove_push, 'Enable','on');
0049     set(H.input_file_view_push, 'Enable', 'on');
0050 end
0051 
0052 %%%%%%%%%%%%%
0053 % File type
0054 %
0055 % reset radiobutton
0056 H = data.H;
0057 group = [H.file_type_meg_radiobutton; ...
0058          H.file_type_eeg_radiobutton];
0059 set(group, 'Value', 0);
0060 
0061 % set radiobutton
0062 switch(data.file_type)
0063     case 'MEG'
0064         set(H.file_type_meg_radiobutton, 'Value', 1);
0065     case 'EEG'
0066         set(H.file_type_eeg_radiobutton, 'Value', 1);
0067     otherwise
0068         error('Invalid File type was specified.');
0069 end
0070 
0071 %%%%%%%%%%%%%%%%%%%%%%%%%%
0072 % Process list
0073 Nprocess = length(data.process_list);
0074 parm_names = cell(0);
0075 focus_line = get(H.process_list_listbox, 'Value');
0076 
0077 for k=1:Nprocess
0078     parm_names{k} = vb_table_query_value(d.type_str_table, ...
0079                                          data.process_list{k}.type);
0080 end
0081 set(H.process_list_listbox, 'String', parm_names);
0082 if focus_line > Nprocess && focus_line ~= 1
0083     focus_line = Nprocess;
0084     set(H.process_list_listbox, 'Value', Nprocess);
0085 end
0086 btn_proclist = [H.process_list_remove_push, ...
0087                 H.process_list_edit_push, ...
0088                 H.process_list_view_push, ...
0089                 H.process_list_upper_push, ...
0090                 H.process_list_lower_push];
0091 if Nprocess == 0
0092     set(btn_proclist, 'Enable', 'off');
0093 else
0094     set(btn_proclist, 'Enable', 'on');
0095 end
0096 
0097 % Activate View button when the selected filter
0098 % can be seen by vb_plot_filter_response.
0099 if ~isempty(data.process_list)
0100     selected_filt_type = data.process_list{focus_line}.type;
0101     response_filters   = {d.TYPE_PROCESSING_HIGHPASS;
0102                           d.TYPE_PROCESSING_LOWPASS;
0103                           d.TYPE_PROCESSING_BANDPASS;
0104                           d.TYPE_PROCESSING_STOPBAND};
0105     set(H.process_list_view_push, 'Enable', 'off');
0106     for k=1:length(response_filters)
0107         if isequal(selected_filt_type, response_filters{k})
0108             set(H.process_list_view_push, 'Enable', 'on');
0109         end
0110     end
0111 end
0112 
0113 %%%%%%%%%%%%%%%%%%%%%%%%%%
0114 % Output MEG/EEG file list
0115 set(H.output_file_listbox, 'String', data.output_files);
0116 selected = get(H.output_file_listbox, 'Value');
0117 if isempty(selected) || selected <= 0
0118     selected = 1;
0119     set(H.output_file_listbox, 'Value', 1);
0120 end
0121 if selected <= 0|| (selected > Nfiles && selected ~= 1)
0122     selected = Nfiles;
0123     set(H.output_file_listbox, 'Value', Nfiles);
0124 end
0125 if isempty(data.output_files) || ...
0126    exist(data.output_files{selected}, 'file') ~= 2
0127 
0128     set(H.output_file_view_push, 'Enable', 'off');
0129 else
0130     set(H.output_file_view_push, 'Enable', 'on');
0131 end
0132 
0133 if ~isempty(data.input_files) && ~isempty(data.process_list)
0134     set(H.exec_push, 'Enable', 'on');
0135 else
0136     set(H.exec_push, 'Enable', 'off');
0137 end
0138 %
0139 % --- After check
0140 %
0141 if nargout ~= 1
0142     error('function caller should receive data object.');
0143 end
0144

Generated on Mon 22-May-2023 06:53:56 by m2html © 2005